site stats

Cultec chambers 330

WebSeptic Chambers. Print ... Cultec. Recharger® 330XLHD 7 ft. Recharger End Unit. Part … WebCONTACTOR ® 100HD. The Contactor® 100HD is a 12.5″ (318 mm) high, low profile chamber and is typically used for installations with depth restrictions or when a larger infiltrative area is required. The Contactor 100HD has …

RECHARGER®180HD 20.5 in / 521 mmMODEL # 180HD - CULTEC, Inc.

WebThe Recharger 330XLHD is a 30.5 in. (775 mm) tall, high capacity chamber. Typically when using this model, fewer chambers are … WebThe CULTEC Contactor and Recharger chambers replace conventional stormwater management systems such as ponds, swales, pipe and stone trenches or beds, or concrete structures. The chambers may be used … bio fingerprinting https://bjliveproduction.com

Faqs - CULTEC, Inc.

WebThe CULTEC, Inc. Stormwater Design Calculator is an MS Excel-based spreadsheet used for designing CULTEC Stormwater Systems. It can be used as a stand alone design tool that generates report outputs based on your parameters. View sample report Current version is: v. 04/20 Download CULTEC Stormwater Design Calculator v. 04/20 … Web20.50 in 521 mm. Installed Length. 6.33 ft 1.93 m. Length Adjustment per Run. 1.00 ft 0.30 m. Chamber Storage. These values are based on the installed length of the chamber. See specifications for installed length. 3.45 ft³/ft 21.81 ft³/unit … Web878 Federal Rd, P.O. Box 280 Brookfield, Connecticut 06804 USA Phone: 203.775.4416 Toll Free: 1.800.4.CULTEC Fax: 203.775.1462 Email: [email protected] biofin india

Stormwater Design Calculator - CULTEC, Inc.

Category:Cultec Recharger® 330XLHD 7 ft. Recharger End Unit

Tags:Cultec chambers 330

Cultec chambers 330

Home Page - CULTEC, Inc.

WebThe Recharger® 360HD is a 36″ (914 mm) tall, high capacity chamber. Typically when using this model, fewer chambers are required resulting in less labor and a smaller installation area. The Recharger® 360HD has the side portal internal manifold feature. HVLV® FC-48 Feed Connectors are inserted into the side portals to create the internal … WebCULTEC Recharger® 330LXHD septic chambers are designed to be used for septic …

Cultec chambers 330

Did you know?

WebCULTEC Plastic Chambers Control rainwater from gutters, patio, driveway and other impervious surfaces Eliminate flooded basements and yards Act as dry wells to contain water from sump pump, washer machine, pool backwash or water softener discharge System Benefits Large storage capacity in small footprint WebThe CULTEC Subsurface Stormwater Management System is a high-density polyethylene (HDPE) chamber system arranged in parallel rows surrounded by washed stone. The CULTEC chambers create arch-shaped voids within the washed stone to provide stormwater detention, retention, infiltration, and reclamation.

WebMar 31, 2016 · Trade name of technology: CULTEC Chambers; model: Field Drain Contactors C4; Contactor EZ-24, 100, 125, and 202; and Recharger 180, 280, and 330XL (hereinafter the "System"). Schematic ... Recharger 330 7.2 4Effective Leaching area is equal to 1.67 times bottom width only. 5. For new construction or an upgrade, the … WebHow Do You Recommend Burying The Cultec Chambers For Paved Traffic Applications? Where Do You Recommend The Placement Of Filter Fabric For A Stormwater Management System? How Do You Control The Water Outflow In A Detention System? What Type Of Maintenance Is Required On The Cultec Stormwater System? How Long Does The …

WebMar 30, 2024 · The Recharger® 330XLHD is a 30.5″ (775 mm) tall, high capacity plastic … WebThe CULTEC Contactor and Recharger chambers replace conventional stormwater management systems such as ponds, swales, pipe and stone trenches or beds, or concrete structures. The chambers may be used for drywells. They may be installed in trench or bed configurations according to site restrictions or client preference.

WebDRAINAGE & SEPTIC: PLASTIC PRODUCTS Plastic Basins and Boxes: “Spee-D Drain” for use in walkways and patios, 4” wide plastic drains with durable 2’ plastic grates in 2’, 4’ and 10’ lengths as well as 90* sections, 3 1/2” deep. …

WebThe CULTEC Contactor and Recharger chambers replace conventional stormwater management systems such as ponds, swales, pipe and stone trenches or beds, or concrete structures. The chambers may be used for drywells. They may be installed in trench or bed configurations according to site restrictions or client preference. biofin insect sprayWebCULTEC SALESPERSON Dominic Turner CALL/TEXT: 581.398.5719 203-775-4416 Ext. 147 FAX: 438-266-4033 [email protected]. AREA REP Kent Frame GeoStorm, Inc. 416.570.4676 [email protected]. EXCLUSIVE DISTRIBUTOR – ONTARIO Stormcon 647.463.9803 407 Deerhurst Drive Brampton, L6T 5K3 Ontario, Canada bio fingerprint checkhttp://www.lawtonadams.com/index.php/drainage-a-septic-plastic-products dai clothesWebcultec stormfilter® 330 designed as a water quality unit. the unit may be used to filter stormwater run-off via pass-thru filtration baffles. stormfilter 330 parameters 1.the chambers shall be manufactured by cultec, inc. of brookfield, ct (203-775-4416 or 1-800-428-5832). 2.the chamber shall be vacuum thermoformed of black polyethylene. daic-woz githubWebThe open bottom and perforated sidewalls of CULTEC chambers maximize infiltrative … biofin insectWebThe Recharger® 330XLHD is a 30.5″ (775 mm) tall, high capacity chamber. Typically when using this model, fewer chambers are required resulting in less labor and a smaller installation area. The Recharger® 330XLHD has the side portal internal manifold feature. Length Width Height Storage Capacity 8.50 ft 52 inches 30.5 inches 474 Gallons daiden welding machine philippinesWeb330XLHD 902HD 902HD EC 360HD 360HD EC Please send me the following (check all that apply) Installation Instructions for CONTACTOR & RECHARGER Stormwater Chambers StormGenie CD Stormwater Management Design Guide Stormwater Product Booklet Please have a representative contact me regarding Stormwater Management System Name … daich stonespread countertop